Stack gas sampling
|
A266 |
|
Low flow sampler
|
low flow heated gas sampler for VOC's, sampling, HF and HCl Flow rates ranging from 0.3 up to 2lpm. The system utilises a heated probe a mass flow control system, giving readings of flow rate in litres per minute and a standardised total volume
|
Polypropylene sample bottles (Changeable) Heated sample probe( monel liner) (Changeable) Monel hosebarb connector Pid heater controller Total corrected volume displayed Flow rate displayed Control type mass flow controlled
mains power 110v Current up to 5 amps weight approx 5 kg
|
|
|
Combustion Analyser
|
A1027 |
|
Greenline 4000
|
Hand Held 4 cell combustion analysers NO,NO2,CO,O2 Data logging upto 250 pts Pt100 temp sensor Battery powered Light weight 1.1kg Download full spec click on "view more" and go to the pdf
|
|
|
|
|
Combustion Analyser
|
A1027 |
|
Greenline 8000
|
High performance Combustion analyser Infra red /electrochemical cell Mcerts type II pending low Nox low CO Oxygen Heated filter Heated line Gas conditoner up to 9 cell measuring options
|
|
|
|
|
Automated GAS ANALYSIS
|
A266 |
|
Stack and Ambient
|
Volatile organics/Gas sampling train see US EPA methods.
Can be used as a simple(easy to use) mass flow controlled sampling unit to monitor for gases such as ammonia,hcl, fluorides.
A sampling train is coupled to the inlet of the unit.The unit has it is own moisture trap into which you place silica gel as an absorbent You nominally would set aflow rate as required which may be for example 1lpm over 30mins. This is typical for most gas sampling. The gas vapour is drawn into the impinger by the sampling unit. The impinger content is sent to the laboratory for analysis. This is a quick,simple test methods.
Flow rates can be set, sampling start and stop times can be set or total volume sampled can be set.
The unit can be programmed in 30 seconds
Sampling volumes are standardised and logged,as are flow rates and dates together with times.
The unit is designed to run from either 110v/220v or 12v
Weight 13kg
|
|
|
|
|
Combustion Analyser
|
A1027 |
|
Quintox
|
Combustion analyzer
This is an inexpensive simple and robust way of doing flue gas monitoring.The unit comes complete with case,cary strap, moisture trap,battery charger, probe, SO2 filter, probe and 15ft sample line 2 x paper rolls.
For hot gases you need to use a cooler.
Ambient operating range: 0 to 40 deg C
Max temp: 40 deg C
| SensorRange | Resolution | Accuracy |
O2 | 0-25% | 0.1% | +/- 0.2% |
CO | 0-10,000ppm | 1ppm | +/- 20ppm |
NO | 0-5000ppm | 1ppm | +/- 5ppm |
NO2 | 0-1000ppm | 1ppm | +/- 5ppm |
CO2 | calculated | | |
Battery power: 12v 6 Ahr (8 full hrs with pump on)
Flue gas probe: Stainles steel shaft with rubber handle
Flue gas hose: 5m/15ft neoprene hose and thermocouple.
Probe dimension: 300mm x 8mm/ 12” x 5/16”
Max probe temperature: 600 deg C
Temperature accuarcy: +/- 1deg C
Pre programmed fuels: natural gas,natural gas2, gascor, town gas, Light oil, heavy oil, propane, butane, anthracite, coke, coal.
Dimensions: 450(L)mmx 230(W)mmx 300mm(H)
Complete case: 9.5Kg
Drier A282K
A light weight peltier cooler
Max flow: 2.5lpm
Nominal Temperature
|
|
|
|
|
|
|
| |
|